2.      Design wind force coefficients for open-topped oil storage tanks focusing on the wind-induced buckling

Yasushi Uematsu, Choongmo Koo, Jumpei Yasunaga

Journal of Wind Engineering and Industrial Aerodynamics, 130(2014) pp. 16-29, 2014.4

 

abstractWind force coefficients for designing open-topped oil storage tanks have been investigated both experimentally and analytically.  First, simultaneous pressure measurements were carried out at many points both on the outside and inside of the wall of a rigid model in a turbulent boundary layer.  A conditional sampling of pressures was made for investigating the pressure distribution at an instant when the external pressure at a reference point, roughly corresponding to the windward stagnation point, became the maximum peak value.  The instantaneous distribution of wind force coefficients, or the pressure difference coefficients at this moment was found to be similar to that of the mean wind force coefficients.   Then, the buckling behavior of thin cylindrical shells was investigated based on a wind tunnel experiment with elastic cylinders.  Furthermore, a finite element analysis of the buckling behavior under static wind loading was carried out.  The results indicate that the buckling behavior is mainly affected by the magnitude and extent of positive wind force coefficient on the windward area of the cylinder.  Finally, a discussion is made of the wind force coefficients to be used for the design of open-topped oil storage tanks, based on the above-mentioned wind tunnel experiments and finite element analysis.

 

3.   LES of unsteady aerodynamic forces on a long-span curved roof

Wei Ding, Mana Nakamura, Yasushi Uematsu

CWE2014, 6th International Symposium on Computational Wind Engineering, Hamburg, Germany, 8-12 June. 2014

 

abstractThe present paper discusses the characteristics of unsteady aerodynamic forces on a long-span curved roof by using LES (Large Eddy Simulation). A forced vibration test in a turbulent boundary layer is simulated to investigate the influences of roof’s vibration on the wind pressure and flow field. It is found that the LES can be used effectively to evaluate the unsteady aerodynamic forces on a vibrating roof in a wider range of reduced frequency of vibration compared with the wind tunnel experiment.

 

4.   宮 城県における鉄骨 造屋内運動場の耐震診断事例に関する調査研究

今 野大輔,植松康

日 本建築学会東北支部研究報告集構造系第77号,pp.79-822014.6

Study on seismic evaluation and retrofiting of steel gymnasiums in Miyagi prefecture

Daisuke KONNO, Yasushi UEMATSU

Proceedings of AIJ Tohoku Chapter Architectural Research Meeting, Vol.77, pp.79-82, 2014.6

  

5.     Local wind pressures acting on walls of low-rise buildings and comparisons to the Japanese and US wind loading provisions

Eri Gavanski, Yasushi Uematsu

Journal of Wind Engineering and Industrial Aerodynamics, 132(2014), pp.77-91, 2014.7

 

abstractThis paper examines peak external wind pressures acting on walls of low-rise buildings using various parameters.  Results indicate that positive pressure distribution is relatively uniform regardless of parameters considered and its magnitude decreases as averaging area size becomes larger.  Large suction pressure distribution occurs at lateral edges of walls and its magnitude does not average out with increasing averaging area size as rapidly as for positive pressure.  Based on these observations, we find that zoning of wall area for design purposes is only necessary for wall suction pressures.  We further find that it is more suitable to base zoning on building height to some extent.  When the present results are compared with the design values in the AIJ Recommendations for Loads and Buildings in Japan, the design values significantly underestimate positive wall pressures for small averaging areas, but the degree of underestimation diminishes as area becomes larger.  Similarly, design values underestimate negative wall pressures up to an area of 10 m2, but begin to overestimate past that point.  A similar observation was made for a comparison with ASCE7-10; however, the degree of overestimation of negative code values at larger areas was smaller than the one observed in the comparison with the AIJ Recommendations.

 

6.   連 棟配置されたオープントップオイルタンクの設計用風荷重

安永隼平,具忠謨,植松

日 本風工学会論文集39巻第3(通号第140)pp.53-622014.7

Wind Loads for Designing Open-topped Oil-storage Tanks in Various Arrangements

Jumpei Yasunaga, Choongmo KOO, Yasushi UEMATSU

Journal of Wind Engineering, JAWE, Vol.39, No.3(No.140), pp. 53-62, 2014.7

 

7.   一 般社団法人日本風工学会・会長就任にあたって

植 松康

日 本風工学会誌39巻第3(通号第140)pp.221-2222014.7

Message from the New President of JAWE

Yasushi UEMATSU

Wind Engineering, JAWE, Vol.39, No.3(No.140), pp. 221-222, 2014.7

 

8.      Window glass design in light of weathering effect

Eri Gavanski, Daisuke Konno, Yasushi Uematsu

The 2014 World Congress on Advances in Civil, Environmental, and Materials Research (ACEM14), Busan, Korea, August 24-28, 2014

 

ABSTRACTWhen severe wind events occur, failure of window glass can be observed quite frequently. Although the main cause of this failure is believed to be wind-borne debris, failure due to wind pressure is also relatively common and numerous studies were performed on estimating window glass plate strength under wind loading. With respect to the estimation of glass strength, a proper determination of initial glass strength, which is the strength before glass is loaded, is important and the weathering effect is known to affect the initial glass strength.  Regardless its importance, few studies have previously been conducted on the weathering effect because a large number of in-service glass plates necessary to obtain statistically significant results can seldom be obtained in practice. However, due to the Great East Japan Earthquake, some buildings in the Faculty of Engineering, Tohoku University were severely damaged and a decision was made that they should be demolished and rebuilt. This allowed us to obtain a large number of in-service window glass plates from one of the buildings before it was demolished.  A coaxial double ring test was performed both on in-service glass plates from the destroyed building and on new plates. Thereby, the reduction of glass strength due to weathering effect was evaluated. By treating the obtained breakage strength as initial glass strength, glass strength was calculated by performing glass strength modeling, which considered the unique characteristic of glass plates (i.e., static fatigue).   Finally, a fragility analysis was performed using the obtained wind load resistance in order to observe the weathering effect on wind speeds in design situations.

 

9.   Evaluation of the strength of elastically-supported glass plates forwind-resistance design of windows

Daisuke Konno, Eri Gavanski, Yasushi Uematsu

The 2014 World Congress on Advances in Civil, Environmental, and Materials Research (ACEM14), Busan, Korea, August 24-28, 2014

 

ABSTRACTStrength and failure characteristics of elastically-supported glass plates are examined by performing full-scale breakage tests and numerical simulation which can predict glass failure pressure. In full-scale breakage tests, three types of wind loading were applied to the specimens, including dynamic loading created based on wind tunnel measurement, up to plate failure. The results are consistent with the assumption that the damage accumulation of glass is independent of loading patterns. In addition, the numerical simulation, which was originally developed for simply-supported glass plates, was modified so that it can be applicable to glass plates elastically supported. The effects of several input parameters for the numerical simulation on the calculate failure pressure were investigated in order to choose the best combination of these parameters for closely replicating the full-scale breakage test results.

 

10.  Design wind loads for open-type framed membrane structures

Yuki Takadate, Eri Gavanski, Yasushi Uematsu

The 2014 World Congress on Advances in Civil, Environmental, and Materials Research (ACEM14), Busan, Korea, August 24-28, 2014

 

ABSTRACTWind force coefficients for designing open-type framed membrane structuresareproposed based on a wind tunnel experiment. Two cases of gable-wall opening are investigated; only one gable wall is open in a case, while both gable walls are open in the other case. For a comparative purpose, a closed-type model is also tested. Wind pressures are measuredsimultaneously at many points both on the external and internal surfaces of the model in a turbulent boundary layer. For discussing the design wind loads on the main wind force resisting systems, focus is on the bending moment involved in the windward column as the load effect. Furthermore, the peak wind force coefficients for cladding designare specified based on the distributions of the most critical positive and negative peak wind force coefficients irrespective of wind direction.

 

11.様々 な地点における風観測データを用いたピークファクターの性状評価

〜 乱れの強さおよび観測高さとの関係〜

赤 星明紀,佐々木亮治,中村修,宮下康一,植松康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.121-1222014.9

Evaluation of the peak factor by using the wind observation data at various points.

The relation between the peak factor, the turbulence intensity, and the height of the observation

Akinori AKAHOSHI, Ryoji SASAKI, Osamu NAKAMURA, Koichi MIYASHITA, Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 121-122, 2014.9

 

12.地 表付近の風の性状と地表面粗度に関連する諸量の関係

そ の3  観測高さがガストファクターに与える影響

佐々 木亮治,赤星明紀,中村修,宮下康一,植松 康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.123-1242014.9

Comparison of characteristics of terrain roughness and ground surface wind

Part 3 Influence of observation height on gust factor

Ryoji SASAKI, Akinori AKAHOSHI, Osamu NAKAMURA, Koichi MIYASHITA, Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 123-124, 2014.9

 

13.竜 巻災害に対する行政の対応項目の整理

2012年 の竜巻に対するつくば市役所へのヒアリングを通じて‐

池内淳子,植松,奥田泰雄

日本建築学会大会学術講演梗概集(近畿)構造Tpp.133-1342014.9

The measures that local government needs tornado Disaster

-Interview to Tsukuba City officials for tornado on May 2012-

Junko IKEUCHI, Yasushi UEMATSU, Yasuo OKUDA

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 133-134, 2014.9

 

14.ダ ウンバーストによる建築物の風荷重に関する研究 その1

植松康飯 田有未,ガ ヴァンスキ江梨

日本建築学会大会学術講演梗概集(近畿)構造Tpp.171-1722014.9

A study of downburst-induced wind loading on buildings  Part 1

Yasushi Uematsu, Yumi. Iida, Eri Gavanski

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 171-172, 2014.9

 

15.ダ ウンバーストによる建築物の風荷重に関する研究 その2

飯 田有未,植松康, ガヴァンスキ江梨

日本建築学会大会学術講演梗概集(近畿)構造Tpp.173-1742014.9

A study of downburst-induced wind loading on buildings  Part 2

Yumi. Iida, Yasushi Uematsu, Eri Gavanski

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 173-174, 2014.9

 

16.膜構造独立上屋の設計用風力係数に関する研究

− 片流れおよびHP型 独立上屋の場合−

武田文義,吉野達矢植松 

日本建築学会大会学術講演梗概集(近畿)構造Tpp.185-1862014.9

Discussion of design wind force coefficients for free-standing canopy roofs of membrane structures

   Fumiyoshi TAKEDA, Tatsuya YOSHINO, Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp.185-186, 2014.9

 

17.妻 面開放型膜構造建築物の構造骨組用風荷重に関する研究

舘祐貴,植松康,ガヴァンスキ江梨

日本建築学会大会学術講演梗概集(近畿)構造Tpp.189-1902014.9

Wind force coefficients for structural for frames of open-type membrane structure

Yuki TAKADATE, Yasushi Uematsu, Eri Gavanski

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 189-190, 2014.9

 

18.補 剛リングがオープントップオイルタンクの座屈性状に及ぼす影響に関する研究

山 口貴之,植松康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.205-2062014.9

Effect of the flexural rigidity of the ring on the buckling behavior of the open-topped oil-tank under wind

pressure

Takayuki YAMAGUCHI, Yasushi Uematsu

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 205-206, 2014.9

 

19.  弾 性支持された板ガラスの強度評価法に関する研究

今 野大輔,ガヴァンスキ江梨,植松 康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.209-2102014.9

Evaluation of the strength of elastically supported glass plates

Daisuke KONNO, Eri GAVANSKI , Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 209-210, 2014.9

 

20.低層建物の壁面に作 用する風圧特性

ガ ヴァンスキ江梨,植松 康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.211-2122014.9

External wind pressures acting on walls of low-rise buildings

Eri GAVANSKI , Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 211-212, 2014.9

 

21.実変動風圧下におけ る外壁システムの耐風性能評価法に関する研究

そ の1PLAPressure Loading Actuator) の基本性能

高 橋麻衣,星野菜紡,ガヴァンスキ江梨,植松康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.239-2402014.9

Evaluation of wind resistance of wall systems under realistic wind loading

Part.1 Characteristics of pressure loading actuator

Mai TAKAHASHI, Natsumi HOSHINO, Eri GAVANSKI , Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 239-240, 2014.9

 

22.実変動風圧下におけ る外壁システムの耐風性能評価法に関する研究

そ の2 金属サイディングを用いた試験体による実大動風圧実験

星 野菜紡,高橋麻衣,ガヴァンスキ江梨,植松 康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.241-2422014.9

Evaluation of wind resistance of wall systems under realistic wind loading

Part.1 Characteristics of pressure loading actuator

Natsumi HOSHINO, Mai TAKAHASHI, Eri GAVANSKI , Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 241-242, 2014.9

 

23.風 外力を受ける高層建物の外装材疲労損傷評価に関する研究

その3:気象観測 データに基づく50年間の疲労損傷評価

寺 崎 浩,植松 康

日本建築学会大会学術講演梗概集(近畿)構造Tpp.243-2442014.9

Fatigue damage evaluation of high-rise building cladding and components subjected to dynamic wind Forces.  Part 3 : Fatigue damage evaluation based on meteorological observation data.

Hiroshi TERAZAKI, Yasushi UEMATSU

Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, Structure I, pp. 243-244, 2014.9

 

24.Wind-induced scattering of permeable unit flooring decks loosely laid on rooftop and balconies of high-rise buildings

Yasushi Uematsu, Yoshiki Shimizu, Yoshimasa Miyake, Yusuke Kanegae

7th International Symposium on Environmental Effects on Buildings and People (EEBP7), Crakow, Poland, October, 20-22, 2014

Abstract: The present paper discusses the mechanism of wind-induced scattering of permeable unit flooring decks loosely laid on the rooftop and balconies of high-rise buildings. First, the scattering mechanism of decks is investigated, based on a blowing test us-ing a blower and actual decks. Then, a simulation model is constructed for estimating the internal pressures under the decks (pressure acting on the bottom surface of decks), based on the unsteady Bernoulli equation and the time history of external pressures on the rooftop and balconies, obtained from a wind tunnel experiment. Combining the simulated internal pressures and the experimentally obtained external pressures, the time history of net wind forces acting on the decks is computed. The threshold wind speed of scatter-ing (scattering wind speed) is obtained by applying the scattering mechanism to the simulated time history of the net wind forces.

 

25.  Design wind force coefficients for free-standing canopy roofs of membrane structures

Fumiyoshi Takeda, Tatsuya Yoshino, Yasushi Uematsu

7th International Symposium on Environmental Effects on Buildings and People (EEBP7), Crakow, Poland, October, 20-22, 2014

 

Abstract: The present study examines the wind-induced behavior of free-standing membrane canopy roofs of various types of roof-supporting systems and presents wind force coefficients for designing such roofs. The effects of roof deformation and roof-supporting system on the wind force coefficients are investigated. The characteristics of wind-induced responses of the roofs are tak-en into account for improving the wind force coefficients that we previously proposed based on the results of wind tunnel experiment with rigid roof models.

 

26.  Relationship between Surface Roughness and Turbulence of Natural Winds near the Ground Surface

Ryoji Sasaki, Akinori Akahosh, Yasushi Uematsu

7th International Symposium on Environmental Effects on Buildings and People (EEBP7), Crakow, Poland, October, 20-22, 2014

 

Abstract: In the wind-resistant design of low-rise buildings, it is important to evaluate the wind loads accurately, both on the structural frames and on the cladding/components. For this purpose, it is necessary to understand the characteristics of natural winds near the ground surface in detail. The present study develops a quantitative estimation method for evaluating the turbulence of winds near the ground surface on the basis of field measurements at various points all over Japan. The characteristics of surface roughness are evaluated on the basis of several factors obtained from a building information database. The relationship between these factors and the turbulence of winds is discussed. The effect of observation height above the ground surface on the turbulence is also investigated.

 

27.Wind Loading on a Hyperbolic Paraboloid Free Roof

Yasushi Uematsu, Yukari Miyamoto, Eri Gavansky

Journal of Civil Engineering and Architecture, Volume 8, No. 10 (Serial No. 83), pp. 1233-1242, 2014.10

 

Abstract: Wind loading on an H.P. (hyperbolic paraboloid) free roof has been investigated on the basis of a wind tunnel experiment.  The roof models of 1 mm thickness were made of nylon resin using laser lithography. The parameters under consideration are the rise to span ratio and slope of the roof. The overall aerodynamic forces and moments were measured by a six-component force balance in a turbulent boundary layer.  Based on a  combination of the lift and moment coefficients, the design wind force coefficients, CNW * and CNL *, on the windward and leeward halves of the roof are proposed. Focus is on the column axial forces induced by wind loading as the load effect for discussing the design wind loads, assuming that the roof is rigid and supported by four corner columns. Indeed, two pairs of CNW * and CNL *, generating the maximum tension and compression in the columns, are provided for each of the two or three wind directions parallel to the roof’s diagonal lines. The proposed values of the wind force coefficients are compared with the specified values in the Australia/New-Zealand Standard for a limited range of rise to span ratio.

 

28.  WIND LOADS AND WIND-INDUCED BUCKLING OF OPEN-TOPPED OIL-STORAGE TANKS IN VARIOUS ARRANGEMENTS

Yasushi UEMATSU, Jumpei YASUNAGA, Choongmo KOO

Sustainable Solutions in Structural Engineering and Construction, pp.333-338, 2014, 2014.10

 

Abstract: Wind force coefficients for designing open-topped oil-storage tanks in various arrangements have been investigated under experiments involving a wind tunnel and a buckling analysis of the tanks. In the wind tunnel experiment, the wind pressures were measured simultaneously at many points both on the external and internal surfaces of a rigid model for various arrangements of two to four tanks. The effects of arrangement and gap spacing of tanks on the pressure distribution are investigated. The buckling of tanks under static wind loading is analyzed by using a non-linear finite element method. A discussion of the effect of wind force distribution on the buckling behavior follows. The authors provided a model of circumferential distribution of wind force coefficient on isolated open-topped tanks in their previous paper. This paper proposes a model of wind-force coefficient for plural tanks in various configurations by modifying the model for isolated tanks.

 

29.竜 巻発生前後の時間経過に応じた被害低減策

201256日 つくば市で発生した竜巻災害を事例として‐

池内淳子,植松,奥田泰雄

日 本風工学会論文集39巻第4(通号第141)pp.79-902014.10

Approach to Tornado Disaster Reduction in Consideration of Progress of the Time before and after Tornado -Case Study of the May 6, 2012 Tsukuba City Tornado Disaster -

Junko IKEUCHI, Yasushi UEMATSU, Yasuo OKUDA

Journal of Wind Engineering, JAWE, Vol.39, No.4(No.141), pp. 79-90, 2014.10

 

30.地上設置型太陽光発電システムの設計用風荷重

植 松康

太 陽エネルギー,Vol.40No.6(通 巻224)pp.29-372014.11

Wind loads for designing photovoltaic systems placed on the ground

Yasushi UEMATSU

Journal of JSES, Vol.40, No.6(No.224), pp.29-37, 2014.11

 

31.観 測高さがガストファクターと地表面粗度に関連する諸量の関係に及ぼす影響

佐々 木亮治,赤星明紀, 植松 康

23回風工学シンポジウム論 文集,pp.13-18, 2014.12

INFLUENCE OF OBSERVATION HEIGHT ON RELATIONSHIP BETWEEN GUST FACTOR AND GROUND SURFACE ROUGHNESS

Ryoji SASAKI, Akinori AKAHOSHI Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 13-18, 2014.12

 

ABSTRACT: When considering the wind-resistant design of low-rise buildings, it is important to evaluate the wind loads accurately, both on the structural frames and on the cladding/components of the buildings. For this purpose, it is necessary to understand in detail the characteristics of natural winds near the ground surface. In the present study, a quantitative estimation method is developed to evaluate the turbulence of winds near the ground surface on the basis of field measurements at various points in urban areas. The characteristics of surface roughness are evaluated on the basis of several factors obtained from a building information database, and the relationship between these factors and gust factor is discussed. The effect of height on the turbulence is also investigated.

 

32.  竜 巻災害に対して行政が対応すべき項目の整理と地域防災計画への反映

池 内淳子,植松康,奥田泰雄

23回風工学シンポジウム論 文集,pp.193-198, 2014.12

APPROACH TO REFLECT TORNADO DISASTER COUNTERMEASURES ON LOCAL DISASTER MANAGEMENT PLAN

Junko IKEUCHI, Yasushi UEMATSU, Yasuo OKUDA

The 23th National Symposium on Wind Engineering, pp. 193-198, 2014.12

 

ABSTRACT: The purpose of this paper is to promote tornado disaster countermeasures for local governments. The actions that local governments have to take after a tornado disaster are arranged. These results are based on the interview given to the officials of the local government that received a tornado disaster, and are classified into four categories based on the disaster phases; that is, prevention, mitigation and preparedness, emergency response, and recovery and rehabilitation. Furthermore, the results are compared with the tornado countermeasures specified in the Saga City Local Disaster Management Plan. It is hoped to specify tornado disaster countermeasures in the Local Disaster Management Plan of the other local governments.

 

33.  低 層建物壁面に作用する外装材用風圧係数の検討

ガ ヴァンスキ江梨,植松康

23回風工学シンポジウム論 文集,pp.253-258, 2014.12

Characteristics of local wind pressures acting on walls of low-rise buildings

Eri GAVANSKI, Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 253-258, 2014.12

 

ABSTRACT: The characteristics of peak external wind pressures acting on walls of low-rise building were examined by using wind tunnel test results performed on models with various roof slopes and eave heights. On one hand, pressure distribution of positive wind pressure is found to be relatively uniform; and hence zoning seems unnecessary. On the other hand, large suctions are observed at the lateral edges of walls, which results in the necessity of zoning. Strong non-Gaussian characteristics are found not only for negative wind pressures but also for positive wind pressures and the probability density does not necessarily become Gaussian when aggregated loads are considered. Comparisons with the specified values in the AIJ Recommendations for Loads and Buildings in Japan were also performed.

 

34.妻 面開放型骨組膜構造建築物の構造骨組用風荷重に関する研究

舘祐貴植 松康ガ ヴァンスキ江梨

23回風工学シンポジウム論 文集,pp.259-264, 2014.12

WIND FORCE COEFFICIENTS FOR DESIGNING FRAMED MEMBRANE STRUCTURES OF OPEN TYPE

Yuki TAKADATE, Yasushi UEMATSU, Eri GAVANSKI

The 23th National Symposium on Wind Engineering, pp. 259-264, 2014.12

 

ABSTRACT: Wind force coefficients on semi-open type structures are proposed on the basis of the result of a wind tunnel experiment. Two types of gable-wall opening are investigated; only one gable wall is open in a case, while both gable walls are open in the other case. Closed-type model is also tested for a comparative purpose. The wind pressures are simultaneously measured at many points both on the external and internal surfaces of the model in a turbulent boundary layer. When discussing the wind force coefficients, focus is on the bending moment at the windward knee of the frame for the pinned-base frame and at the windward base for the fixed-base frame. Based on the result for the most critical condition, we propose the wind force coefficients for the main wind force resisting systems by using the LRC method, which can be used in the frame of conventional gust effect factor approach.

 

35.数 値流体解析を用いた大スパン園芸用鉄骨ハウスの最適断面形状の提案

金 南昔,植松康

23回風工学シンポジウム論 文集,pp.301-306, 2014.12

INVESTIGATION OF THE OPTIMUM CROSS-SECTION OF GREENHOUSE WITH LONG SPAN BASED ON CFD

Namseok KIM, Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 301-306, 2014.12

 

ABSTRACT: In this study, we reproduced the results of the wind tunnel experiments on a greenhouse with wing-like cross-section (Uematsu 2004) by CFD. We examined the appropriate analytical conditions for the boundary layer turbulence and compared the results with the experimental ones. From the comparison we confirmed the validity of the analytical model. Based on the results of a parametric study in which the heights of windward and leeward walls, curvature of the roof etc. were changed over a wide range. We propose on optimum cross section on of the wing-shaped greenhouse. This cross-section reduces the drag force significantly compared with the conventional ones. 

 

36.通 気性のある屋上目隠しパネルに作用する外装材用風荷重の検討

相 原知子植 松康

23回風工学シンポジウム論 文集,pp.391-396, 2014.12

A STUDY OF WIND LOADS ON PERMEABLE PANELS PLACED ALONG THE PERIMETER OF THE ROOFTOP OF A HIGH-RISE BUILDING

Tomoko AIHARA, Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 391-396, 2014.12

 

ABSTRACT: Permeable materials such as louver and punching metal are used as an outer skin attached to the outside of building walls. However, the wind loads acting on such a permeable material have not been clarified. In the present study, a wind tunnel test is performed to investigate the wind loads on permeable panels attached along the perimeter of the rooftop of a high-rise building. The permeable outer skin is modeled by a thin metal plate with rectangular holes.  The porosity and size of the openings are changed in the test. The effects of those parameters on the wind loads acting on the outer skin are understood through the test.

 

37.風 外力を受ける高層建物の外装材疲労損傷評価に関する検討

寺 崎 浩,植松 康

23回風工学シンポジウム論 文集,pp.397-402, 2014.12

FATIGUE DAMAGE EVALUATION OF CLADDING AND COMPONENTS OF HIGH-RISE BUILDINGS SUBJECTED TO DYNAMIC WIND FORCES

Hiroshi TERAZAKI, Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 397-402, 2014.12

 

ABSTRACT: The cladding and components of high-rise buildings are always exposed to dynamic wind forces. The wind forces are characterized by a long duration compared with seismic forces.  For example, during a strong typhoon, strong wind lasts for a couple of hours. The structural frames of high-rise buildings are usually designed so that the stresses involved in the structural members are almost in the elastic range for the design wind load with a return period of 500 years. On the other hand, in many cases, the cladding and components are designed based on the short-term allowable stress for the design wind load with a return period of 50 years. Therefore, they may be damaged by fatigue during the building’s lifetime.  In the present paper, the characteristics of fatigue accumulation in the cladding and components of high-rise buildings are investigated based on the results of a wind tunnel test and the observation data about 50 years at 14 meteorological observatories in Japan.

 

38.実 変動風圧下における金属サイディングを用いた外壁システムの耐風性能試験

橋麻衣星 野菜紡ガ ヴァンスキ江梨植 松康

23回風工学シンポジウム論 文集,pp.403-408, 2014.12

EXPERIMENT ON WIND RESISTANCE OF WALL SYSTEMS UNDER REALISTIC WIND

LOADING

Mai TAKAHASHI, Natsumi HOSHINO, Eri GAVANSKI Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 403-408, 2014.12

 

ABSTRACT: Wall systems of low-rise buildings have commonly failed during extreme wind events, such as typhoons and tornadoes. In order to understand the failure mechanism of wall systems in detail, full-scale experiments have been conducted using wall specimens with metal sidings assembled in the same way as actual walls. Two types of loadings, i.e., step-up loading and realistic wind loading generated from wind tunnel data, have been employed. The results indicate that there is no significant difference in wall capacity obtained from different loadings, although failure mode progressions of the wall systems under different loading types exhibit a clear difference.

 

39.オー プントップオイルタンクの風による座屈性状に関する有限要素解析

− ウィンドガーダーと風力分布の影響−

山 口貴之安 永隼平植 松 康

23回風工学シンポジウム論 文集,pp.409-414, 2014.12

FINITE ELEMENT ANALYSIS OF BUCKLING BEHAVIOR OF OPEN-TOPPED OIL-STORAGE TANKS UNDER WIND LOADING 

- EFFECTS OF WIND GIRDER AND WIND FORCE DISTRIBUTION –

Takayuki YAMAGUCHI, Jumpei YASUNAGA, Yasushi UEMATSU

The 23th National Symposium on Wind Engineering, pp. 409-414, 2014.12

 

ABSTRACT: The present paper investigates the buckling behavior of open-topped oil-storage tanks based on a finite element analysis. The distribution of wind force coefficients on two or three tank models in various arrangements, together with an isolated model, are measured in a wind tunnel. The results on the mean wind force coefficients are used for the buckling analysis.  First, the fundamental characteristics of buckling behavior are discussed with isolated models. Then, the effects of flexural rigidity of wind girder at the top of the tank on the buckling load and mode of tank shells are investigated. Finally, the effect of wind force distribution on the buckling load is discussed. The results indicate that the distribution of positive wind force coefficients in the windward area affects the buckling behavior significantly.  The buckling load decreases significantly for some arrangements.

 

40.Advances in Wind-resistant Design and Wind Resistance Evaluation in Japan

Yasushi UEMATSU

Steel Construction Today & Tomorrow, No.43, pp.1-2, 2014.12

 

41.Unsteady aerodynamic forces on a vibrating long-span curved roof

Wei Ding, Yasushi Uematsu, Mana Nakamura, Satoshi Tanaka

Wind and Structures, Vol. 19, No. 6, pp.649-663, 2014.12

 

Abstract: The present paper discusses the characteristics of unsteady aerodynamic forces on long-span curved roofs. A forced vibration test is carried out in a wind tunnel to investigate the effects of wind speed, vibration amplitude, reduced frequency of vibration and rise/span ratio of the roof on the unsteady aerodynamic forces. Because the range of parameters tested in the wind tunnel experiment is limited, a CFD simulation is also made for evaluating the characteristics of unsteady aerodynamic forces on the vibrating roof over a wider range of parameters. Special attention is paid to the effect of reduced frequency of vibration.  Based on the results of the wind tunnel experiment and CFD simulation, the influence of the unsteady aerodynamic forces on the dynamic response of a full-scale long-span curved roof is investigated on the basis of the spectral analysis.

 

42.書評 新版 雪氷辞 典 公益社団法人 日本雪氷学会編(古今書院)

植 松康

日 本雪工学会誌,第31巻, 第1号,pp.30-312015.1

 

43.風洞実験による風環 境評価の精度に関する研究

− 樹木の防風効果と基準点の風向変動が及ぼす影響‐

藤 元栄行,猿川明,宮下康一,中村修,植松康

日 本風工学会論文集,40巻 第1(通 号第142)pp.1-72015.1

Study on the Accuracy of Wind Environmental Assessment by Wind Tunnel Experiments

-Effects of windbreak of trees and wind direction fluctuation at the reference point on the estimated results-

Hideyuki FUJIMOTO, Akira SARUKAWA, Koichi MIYASHITA, Osamu NAKAMURA,

Yasushi UEMATSU

Journal of Wind Engineering, JAWE, Vol.40, No.1(No.142), pp. 1-7, 2015.1

 

44.高層建物の帳壁緊結 部疲労損傷評価用風外力の検討

寺 ア浩,植松康

日 本建築学会構造系論文集,第80巻, 第708号,pp.207-2172015.2

Characteristics of wind forces acting on external wall binders of high-rise buildings

from the viewpoint of fatigue damage

Hiroshi TERAZAKI, Yasushi UEMATSU

Journal of Structural and Construction Engineering, Transactions AIJ, Vol.80 No.708, pp.207-217, 2015.2

 

Abstract: The present paper discusses the characteristics of wind forces acting on the external wall binders of a high-rise building based on the results of a wind tunnel experiment from the viewpoint of fatigue damage. Special attention is paid to the binders connecting the external curtain walls and the structural frames. A wind force direction conversion factor for the relation between wind force and member stress is introduced into the fatigue evaluation together with the normalization of stresses. Furthermore, a discussion is also made of the influence of mean stress on the fatigue damage, which depends on the wind direction and speed.

 

45.Design wind loads for open-topped storage tanks in various arrangements

Yasushi Uematsu, Jumpei Yasunaga, Choongmo Koo

Journal of Wind Engineering and Industrial Aerodynamics, 138(2015) pp. 77-86, 2015.3

 

Abstract: The present article proposes a model of wind force coefficient for designing open-topped storage tanks in various arrangements; main focus is on oil storage tanks.  In our previous paper, we discussed the design  wind force coefficients for isolated tanks, based on wind tunnel experiments of wind pressure distributions and buckling as well as on a finite element analysis of buckling under static wind loading.  In practice, however, more than two tanks are constructed in various arrangements in a site.  In such cases, the wind force distribution and the resultant buckling behavior of tanks may be affected by the arrangement significantly.  Therefore, the present article focuses on the grouping effect on the wind force distribution and the buckling behavior.  First, the wind pressures are measured simultaneously at many points both on the external and internal surfaces of a rigid model for various arrangements of two to four tanks in a turbulent boundary layer.  The effects of arrangement pattern and gap spacing of tanks on the pressure distributions are discussed.  Then, the buckling of tanks under static wind loading for various arrangements is analyzed by using a non-linear finite element method.  The results indicate that the distribution of positive wind force coefficient in the windward area affects the buckling behavior significantly.  Finally, based on the results obtained, we propose a model of wind force coefficient on tanks in various arrangements by modifying the model for isolated tanks that we proposed in our previous paper.  For evaluating the design wind loads a gust effect factor approach is employed.  The wind load evaluation is based on the quasi-steady principle and therefore the resonant effect is not taken into account. 

                              

46.201421416日 の大雪による構造物の被害

‐ 群馬県におけるカーポート並びに農業用ハウスの被害を中心として‐

植 松康

東 北地区災害科学研究,第51巻,pp.165-1702015.3

Damage to structures due to heavy snow during February 14 to 16, 2014

- Mainly on the damage to carports and greenhouses in Gunma Prefecture -

Yasushi Uematsu

Tohoku Research Group for Natural Disaster Science, Vol.51, pp.165-170, 2015.3

 

47.妻面開放型骨組膜構 造建築物の構造骨組用風力係数並びに外装材用ピーク風力係数

高 舘祐貴,植松康,ガヴァンスキ江梨

膜 構造研究論文集2014No.282015.3

Wind loads on the main resisting systems and cladding of open-type framed membrane structures

Yuki Takadate, Yasushi Uematsu , Eri Gavanski

Research Report on Membrane Structures 2014, No.28, 2015.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

付録   平成26年 度  修 士学位論文及び卒業論文題目一覧

 

 

 

博士学位論文

寺ア  浩  風外力を受ける高層建物の外装材疲労損傷評価に 関する研究

金  南昔  研究形態制御による風力低減効果を利用した耐候 性園芸用鉄骨ハウスに関する研究

 

 

修士学位論文

  山口 貴之  風荷重を受けるオープントップオイルタンクの座屈・振動に対するリングの

補剛効果に関する研究

今野 大輔  強風下における窓システムの挙動と耐風性能評価 に関する研究

橋 麻衣  金属サイディングを用いた外壁システムの実変動 風圧下における挙動と

耐風性能評価法に関する研究

 

卒業論文

  橋 和也  園芸用パイプハウスの風・雪荷重による崩壊過程に関する研究 

橋本 幸治  円筒形独立上屋の設計用風力係数に関する研究

渡部  慶  金属サイディング固定部の頭抜け破壊を対象とし た耐風性能評価に関する研究

 

 

 

 

   

 


2